    Madrab replied to the thread Radiator tail not coming off.
    That's a modern standard tail - the rad HEX key will only fit the old standard union type tails, i.e - the one on the left in the pic...
    • 1765896072992.png
    • 1765896263855.png
  • Madrab
    Madrab replied to the thread Bypass valve.
    How far away is the pipe stat sensor from the boiler and is the sensor properly bonded to the pipe with thermal paste? Have you cross...
  • Madrab
    That's 2 different functions. The system water (CH) control on the boiler will still control the actual system water temp out to the...
  • Madrab
    No reason why not. Just keep the loops sealed so there's no ingress of anything until they are needed and then connect up, flush and...
  • Madrab
    Madrab replied to the thread How Good are New Toilets?.
    I think everyone needs more fibre in their diet :unsure: :LOL:
  • Madrab
    Madrab reacted to Hugh Jaleak's post in the thread 110mm solvent Tee question with Thanks Thanks.
    Snug? It should be fairly tight, if you've got the reducer in the socket without using any sort of Lubricant, that says to me the...
  • Madrab
    Madrab replied to the thread How Good are New Toilets?.
    If it's a concealed LL cistern then fit a Thomas Dudley and throw away the 6L box ;)
  • Madrab
    Madrab reacted to Hugh Jaleak's post in the thread Once more unto the breach with Like Like.
    As long as there is a clear, open, constantly rising path from the boiler to the Vent, that satisfies the safety aspect. Ideally the...
  • Madrab
    Madrab replied to the thread Once more unto the breach.
    +1 - the standard for a combined feed and vent would be 22mm all the way. Also, they aren't really a standard as they can be a bugger...
  • Madrab
    Madrab replied to the thread Help! Bar Shower Valve Issue.
    Oh dear - as suggested - if you have set it up so it uses a fixing kit, then it needs to be bang on 150mm and if there's absolutely no...
  • Madrab
    Madrab reacted to denso13's post in the thread Help! Bar Shower Valve Issue with Like Like.
    Unfortunately, no. No play at all if you make sure the pipes have a gap around them to the tiles?
  • Madrab
    Madrab replied to the thread 110mm solvent Tee question.
    There shouldn't be any difference TBH - all 110mm PVC-u pipe would normally be able to fit either push fit or solvent weld couplings -...
  • Madrab
    Madrab replied to the thread 110mm solvent Tee question.
    Most soil pipe these days is PVC-U, even the single (ring) socket ended pipe and as long as it is PVC-U then it can be glued. Most...
  • Madrab
    Madrab reacted to Hugh Jaleak's post in the thread 110mm solvent Tee question with Like Like.
    As above, all 110mm stuff, above and below ground, solvent or pushfit should be interchangeable, it's the Tool Station stuff that seems...
  • Madrab
    Madrab replied to the thread 110mm solvent Tee question.
    The reason I ask is the TS have a make of plastic called Aquaflow and it seems to be a different size to the other manufacturers. Every...