gledhill

  1. G

    Gledhill Torrent not Filling up from Header Tank. No Water in P Flow.

    Hi This is an issue which is causing great confusion. I bought a house in September 2020 and installed a wood fired heating system with a Gledhill Torrent 210. The thermal store is in the original boiler cupboard and the header tank is in the attic. The people who installed it didn't replace...
  2. M

    Replacing boiler from a vented to a sealed system.

    I currently have a Glow Worm Flexicom 24hx condensing boiler (13 years old) on the ground floor and a water tank and vented expansion tank in the loft. My home is a detached chalet style bungalow, ground floor and first floor with a small loft area above. It has 4 bedrooms with around 15...
  3. B

    Intergas HRE 30/36 Thermal Store

    Hi, I appear to have an issue with my Intergas boiler connected to my thermal store. It is recommended to keep the thermal store (Gledhill TGH350) at 75c. I have the boiler set at 85c, but after taking the boiler flow temp earlier (before CH came on) at the boiler and at the thermal store, it...
  4. L

    Help please: Pulsacoil 3 thermistor fault

    Good evening all, I hope someone can help. I have a PulsaCoil 3 that may or may not be on its last legs. The manual tells me that a flashing red LED on the circuit board means a 'pumped return thermistor failure'. Unfortunately I can't seem to find out where the thermistor is or even what it...
  5. I

    Vented Thermal Store Installation

    Hi - I need to replace an old vented thermal store because the eco7 immersion has gone and the plumber has advised that it's seized in place and the whole tank will need to be replaced. The tank in question is a Gledhill Torrent (which I don't think are made now) but I've looked around and it...
  6. A

    Replace my gledhill pulsacoil 2000

    So after nearly 16 years looking to replace my gledhill pulsacoil 2000 what with insurance etc its virtually had everything replaced over time except tank. So my question 1 bedroom apartment with 1 shower what are your thoughts on gledhill pulsacoil eco stainless 150.Suitable replacement no oil...
  7. C

    Systemate 2000 Thermal store

    So, after my other thread was locked this is the latest: Initial problem was hot water fluctuating SO BG came out and did the following -New PCB -1x new water pump replacement of sensors the problem was now not fluctuating but the water not warming at times in the day perhaps when the...
  8. J

    Pulsacoil 3 problem

    I have a Pulsacoil 3. The pump was pulsing for prolonged periods even when not running the hot tap so I changed both the DHW wet sensor and the PHE dry sensor. Now when I run a hot tap the pump starts for approx. 5 seconds then switches off. If I close then reopen the tap the same happens. If...
Back