megaflo

  1. C

    Cold water Crossover problem?

    I have a Megaflo cylinder which is probably 20-25 yrs old. I recharge the air gap around every 6 months. All my taps and showers are direct-fed mixers. Thought I might have a problem when hot water from cylinder (pipes there are both hot) is coming out of mixer taps either cool, warm, sometimes...
  2. O

    Incorrect wiring? Hot water temperature ignored.

    Hi all, I have got a new Vaillant EcoTec 418 installed recently and noticed that the set hot water temperature is being ignored, instead it gets generated by flow temperature. Also diagnostics menu says that DHW hours are 0. Could this be a result of an incorrect wiring? I'd like to set DHW...
  3. B

    Shutter the mains water on holidays

    Hi, I am planning on going away in December for a week, and I was thinking of shutter the main water to avoid any surprises when I come back. I live in the UK, in a flat, on the top floor. I have a Megaflo Unvented Cylinder. Is it okay to close the main water for the week I am away? I have no...
  4. P

    Low water pressure system boiler

    Hello, we've Recently moved into a new house which has a modern looking unvented Worcester boiler with a megalo tank. Water pressure in the property is pretty disappointing and flow from both hot and cold taps is no where near our previous house. Doing a bit of spring cleaning and bled all the...
  5. nmg196

    Is moving to mains pressure hot water possible with only 7 litres minute?

    We are considering a loft conversion which may require removal of the cold water tank. However I've read that water pressure should be at least 10 litres per minute for something like a Megaflo and having measured ours a few times, it's only about 6 or 7 litres a minute. Are there any...
  6. R

    Megaflo Eco Plus 300i Leak

    Hello We have a Megaflo Eco Plus 300i installed almost 2 years ago and two of the ports (not sure if that's the right way) were left unused and they are dripping water. I am not sure if this is an installation fault or a defect with the cylinder. Below are two images of the leak: I'm not...
  7. Jennifer153323

    Megaflo dd145 Economy 7 water tank issue

    Hey all. I've just moved into a new flat with economy 7 so we have night storage heaters and a night heating water cylinder. It's 145L, but we only get half, maybe not even that before the water is freezing. The whole tank seems to be heated in the morning as it feels slightly warm on the...
  8. J

    Megaflo losing hot water pressure

    Wondering if anyone can help. We live in a "new build" house that is c20 years old with a megaflo system as old as the house! In the last year or so it seems to be losing pressure quite a lot The megaflo is on the middle floor and when I run a shower on the middle floor the hot water...
  9. M

    Replacing lost water from replacing 2 towel rads on condensing boiler and megaflo system

    I’m going to be replacing 2 towel radiators like for like and have an ideal Icos HE12 condensing boiler with a megaflo cylinder and tank in loft. I’m aware of what I need to do to change radiators but don’t know how to replace the water that will be lost from the 2 old towel radiators as not...
  10. M

    Changing a towel radiator on a megaflo system

    Hi, I’m planning on replacing a towel radiator (like for like size) and had a few questions I’m hoping someone could help me out with. I plan to isolate the rad at the valves at the base of the rad, drain it into a bucket (using the bleed valve to release all the water), install and connect...
  11. 2

    Changing Vented S plan to Unvented S Plan

    Good evening all, I’m a drainage engineer with a plumbing background. My property is an old 1930’s, has an indirect vented cyclinder, f+e in loft and also water tank storage in loft. Would like to replace the vented with an unvented. Same location as existing, really good mains pressure on 15mm...
  12. J

    Help with Megaflo/Vaillant EcoTEC 415

    Hi there - newbie here looking for some help. I am not gas safe registered, and not looking to do this on a DIY basis, but I need to know what to tell an engineer when they visit. The boiler is on a Corgi service plan/warranty (which I will discontinue soon). Last summer the property had a...
  13. A

    Megaflo cylinder water leaking through tundish

    Hi everyone, I’ve been having an issue with my megaflo direct unvented cylinder, When I turn the cylinder on either boost or off peak, the water leaks though the tundish and keeps going. I’ve followed the instructions and repressurised the megaflo but have had the same issue. I thought this...
  14. M

    Newly installed Combi/Megaflo and Immersion heaters

    I need some help! I have recently had a small extension to our 3 bed semi and with the work they have moved our boiler from the kitchen to the loft and as the water pressure upstairs was too low have installed a megaflop as well. I connected our smart metre earlier in the week and we are...
  15. D

    Danfoss TP9000, TP5000 & Smart Heating

    Hello all, I'm thinking of buying either Tado, Hive or Nest for my house. I live in a relatively new build 3 story townhouse in the UK with the Danfoss TP9000 thermostat / hot water programmer on the ground floor next to my Ideal Logic 15 boiler, a Danfoss TS2 sensor in the living room. Then...
  16. D

    Megaflo scale problems - advice required on descale.

    Hello and happy new year. I'm not a plumber, I know you need an unvented ticket to do this work, I've done all I can, I'm just looking to clue up so I know the job will be done right. Megaflo 210i Unvented Indirect cylinder installed in new build house 7 years ago. Problems just started in the...
  17. O

    Megaflo D70 1 Shower

    We have a Megaflo D70. Should it be able to keep up with the use of 1 shower continuously? We seems to run out of water after a 10 minute shower at the moment. I don’t think there is another boiler in the system - should there be? ... the property has electricity only.
  18. G

    Water pressure drop to loft with unvented cylinder

    Hi all. We are having trouble with water pressure from our unvented hot water cylinder tank (a.k.a megaflo/megaflow). Over time, the pressure has reduced so much that we can't get any decent flow rate from the taps in the loft. Ground floor and first floor are very powerful as you can see on the...
  19. happydays129

    megaflo cylinder water dripping through tundish

    Hi everyone, I have my megaflo unvented water cylinder installed a year ago. Now i noticed when heating, water dripping through tundish. I have contacted engineers and the scheduled visit is 2 weeks later (Crying). I am wondering is it safe still to use water cylinder while water dripping...
  20. P

    Mega flo again.

    Hi All. Does not matter what ever i google for advise and help on a Megaflo all the good advise comes back to this forum! Looks like this is the place that you pros hang out too! I am not a plumber so hope I'm welcome and to be honest most of my trouble shooting has come from here too. So...
Back
Top