rsj

  1. S

    RSJs not quite level, acceptable tolerances?

    We are in the process of having the chimney removed. So the builders have just put in two RSJs (152x152x23-5350mm). They sit on engineering bricks and steel plates at both ends. One end was chamfered to fit the roofline. The RSJs sit on 10mm steel plates at the roof side and 15mm plates at the...
  2. S

    Drilling into RSJ/I-Beam - risks (structural, asbestos, etc)

    Hi all I have started drilling into the wall above our French doors downstairs to try and fit a curtain pole, and appear to have hit an I-Beam/RSJ. No idea when it was installed - the house is early 1900s, so any time after then. At this juncture, I’m wondering what the risks are of me...
  3. J

    Door frame cut adjacent to U-Beam - potential corrective action needed

    Guys - hoping someone can provide some advice on an issue spotted whilst completing a garage conversion. 3 years ago a previous builder cut a door space into an internal wall. At the time, i had no reason to question it. I recently contracted another builder to complete the work - he mentioned...
  4. S

    BLOCKWORK layout FOR EXTENSION

    Hi, New here! Not an expert so looking for pointer(s). I have the layout as shown and unsure how to best set blocks for minimum cuts etc... but dont want to go moving walls, windows and piers and changing window sizes more than a few cm as theres reasons.. I have attempted, but unclear about...
  5. N

    (1950’s) RSJ the wrong way around

    I’ve recently bought a terraced house and found out it used to have a double doorway between the front and back room. Cut a hole in the plaster to expose above the doorway to check if it’s suitable for restoring. The doorway has been breeze blocked up, the casing is still there and it seems...
  6. A

    Glazing on RSJ with sliding doors

    ~Vaulted kitchen asymmetric roof single storey extension ~Block work with cavity supporting Catnic type RSJ ~Bespoke glazing (2 x triangular) on RSJ ~Sliding doors under RSJ ~Ali cladding C section over external of RSJ My concern pre door/glazing install is the detail on the RSJ with the...
  7. K

    Loft conversion - temporary support for purlin during floor beam install

    I’ve attached a drawing to show the existing, temporary and final diagrams to help show the question. The structural engineer has designed our loft with 2 floor steels and a ridge steel. The installation of the first floor steel (beam A) is simple, as nothing needs to be removed to install it...
  8. CrossWise

    Will a window lintel be ok above French doors?

    Hi, I have purchased an off the shelf French door 2090mm x 1190mm to be fit in place of a window which is around 2000mm wide with the top of the window being around 2200 above the DPC. The house is a mid 70’s build standard cavity wall construction. I want to fit the doors tight to a finished...
  9. S

    Rsj on load bearing wall

    Opening of 2m steel size of 203x102x23 sat on 440x215x102 pad stones. Pillar either end of 600mm original single skin brick work supporting floor joists and and a single skin wall above going up to loft. This was done by a friend of mine. Is it ok
  10. BjBoomer

    RSJ might not be compliant (Scotland) (Ed.)

    Needing some advice. I'm. In Scotland and we got plans and drawings etc to knock a load bearing wall down and put up Rsj, got all the permissions, structural e gineers sizing and all that. Had loads of problems with the job, loads, turns out the wall wasn't made of brick it was poured concrete...
  11. A

    Rsj or not

    Ok bit of a complicated one. I am in a converted flat in an industrial building that has concrete floors and ceilings think car park! I am removing stud walls to create open kitchen, living room. The stud walls are not structural to the building as they are not supporting concrete however I...
  12. T

    Steel Beam Installation on Engineering Bricks

    Hi all, looking for some advice on what my builder has done here. The project is a single story flat roof extension 6m x4m, with 4m bi-fold doors. The builder has placed the steel beam across the bi-fold door opening and has chosen to use 3 engineering bricks on both leafs of the wall instead...
  13. T

    Steel Beam Installation on Engineering Bricks

    Hi all, looking for some advice on what my builder has done here. The project is a single story flat roof extension 6m x4m, with 4m bi-fold doors. The builder has placed the steel beam across the bi-fold door opening and has chosen to use 3 engineering bricks on both leafs of the wall instead...
  14. R

    How to support Rafter on RSJ

    We are planning an extension that will abut to our pitched roof. This will involve cutting back rafters and replacing the roof plate with an I-Beam. I would like to understand how this should be installed to continue to support existing rafters please. The below shows 2 options of how I envisage...
  15. D

    Hang curtains on rsj problems

    Hi, I’ve a 4M sliding door with a universal steel beam above it and I’m trying to hang curtains by drilling into the underside of the steel and affixing the mountings. I’ve bought HSS drip bits (dewalt) and self drilling (not self tapping) screws (4.2mm x 50mm). Nothing seems to work. This is a...
  16. E

    Replacing render on external RSJ

    Hi folks, I'm ripping out two sets of old patio doors to be replaced next week with aluminium bifolds. The RSJ across the top of the apeture has been rendered externally in a way which doesn't match the style of the rest of the house. I've realised there might be an opportunity to fix this...
  17. T

    Need help on RSJ condensation

    Hello, today I've seen some patches on plasterboards and it was getting wet without any leakage. Upon further investigation, condensation on steel beems were seen.. before plastering it over, please can someone recommend what it needs to be done? (Appreciate if you can give me a name or link to...
  18. N

    Lintel Under an RSJ

    Hi All, New to the forum so apologies if that has been covered in an earlier post, but I couldn’t find anything! I have a 2 storey Victorian built house and I’m looking to move the doorway to our lounge more towards the centre of the room. But my problem is, there is an RSJ around 3.4m long...
  19. R

    RSJ Help

    We've been having a Dorma loft conversion done, the build included the need for 5 RSJ's. One of the main issues we had been facing was freshly plastered ceilings cracking on the 1st floor, which effectively were directly below 3 of the 5 RSJ's. I decided to rip the ceilings down, I found that...
  20. A

    Damaged brickwork around lintel

    Hi all, hoping someone can help with some concern I have with a wall in our flat roof garage. There are cracks in the brickwork where the previous owner looks to have drilled some holes. The issue is there is the door frame and RSJ above which looks like it could collapse. Trying to understand...