  1. L

    Unpleasant smell in 2 bathrooms

    Hi I have this issue in my house where the main bathroom upstairs, and the downstairs toilet, both have a strange unpleasant smell, I'm assuming sewer-y. The en-suite is fine, although the previous owners did some dodgy renovation and behind the vanity unit is a massive hole in the wall into the...
  2. Kezzo

    Stack soil pipe issue

    Hello all, I've had a leak with the shower fitting which, which is now resolved. However I had to smash out some tiles to expose the piping. I noticed that my stack pipe is filthy, and wondered why it is has these rust trails (image 1 & image 2). I'm wondering if this is an issue, I'm guessing...
  3. M

    En suite soil pipe advice

    I'm considering to build an en suite in the attic room of my house. Its a 1890s terrace fairly standard in the North of England. There is pipework up to the attic level since there was previously some sort of tank or immersion heater in the attic so it should be able to be plumbed in. My concern...
  4. Malpighiales

    Advice needed on roof structure

    We're in the process of buying a mid-terrace Victorian/Edwardian (estimated at 1900) house and have just received our Home Buyer's Survey. Unsurprisingly, given the age of the property, it gives the impression the place is about to fall down! Most of the issues are things you'd expect of a...
  5. T

    What fitting(s) for plumbing toilet and shower into soil stack

    I am adding a new bathroom on the first floor of my house and there is limited space to run the drains to the existing soil stack. I have bought a branch connector for the soil pipe (see link) and was hoping to be able to join the shower and basin drain into one of the 40mm side bosses but have...
  6. S

    Should my bathroom waste be vented?

    Hi I've got a recently built extension with a bathroom. The shower trap is letting sewerage smells come up from it. I've been doing a bit of research and I'm thinking that the issue may be that the soil stack is not vented. The waste from the shower, bath and basin connect to this stack on the...
  7. A

    Smell coming from en-suite...

    Hi, any advice would be greatly appreciated. I've noticed a soil/waste smell coming from the en-suite for a few months. Most of the time it's quite faint but on occasions it can be quite noticeable. I think I've narrowed it down to an open stack pipe which vents directly into the loft above the...
  8. H

    Non vertical Soil Stacks

    I am working on a project where a (proposed) internal Soil stack clashes with a partition. It is being proposed that the stack is vertically offset from the vertical by ~5 degrees (300mm over 3.3m). I am struggling to find anywhere within CIBSE / BS that mention offsets from the vertical. Does...
  9. J

    Replacing soil pipe stack and vent (plus running from new toilet location)

    Hello, Can someone please confirm the below as I can not seem to find the right section and my local Building control officer department seems all on holiday. **This is not a thread about adding a toilet, it covers only moving the existing one from outrigger wall to ide return wall.**...