We are covering our garage and have painted a liquid DPM. We then plan on adding 50mm of celotex to the floor, with some timber supports in places around doors and where gym equipment will be as we've read this is suggested. We can't seem to find any specific details though on how we construct...
Hello all,
I posted a forum post here about a poor boiler install and have now asked roofers to have a look in the coming week at the crossbeam the engineers cut significantly when installing the boiler...
There was a hidden leak under my suspended timber floor. The timbers developed wet rot and the surrounding space became mouldy.
The area has now been replaced with fresh timber joists, and the leak has been fixed.
I'm concerned that mould could occur again. What is the best wood treatment to...
Hi all,
I recently purchased a home and found water coming through the ceiling in the upstairs bedroom. Turns out that the loft skylight seals perished and water had been seeping through, onto the joist, going down it and eventually to the ceiling on the floor below. The window will be replaced...
HI,
I'm currently in the process of building sleeper walls in my garden with new treated sleepers. I started this a while back with 2400x200x100 sleepers and now just ordered 5 more of the same size to complete the project. The 5 that arrived all have different widths and depths. I.e one will...
Hi,
I'm putting up a freestanding patio (5 x 2.6m) with insulated roof panels on top. I've got 6 post footings at the moment but wanted to eliminate the middle 2 posts and just have 4 posts. If I'm using treated pine what size beam would span the 5m? Or is that too far? For roof load, depth is...
Hi,
I'm putting up a freestanding patio (5 x 2.6m) with insulated roof panels on top. I've got 6 post footings at the moment but wanted to eliminate the middle 2 posts and just have 4 posts. If I'm using treated pine what size beam would span the 5m? Or is that too far? For roof load, depth is...
Our chippy has chocked up the ends of the double beams (2 of c24; 170x47mm, bolted together) around our new stairwell with a short small softwood wedge (about 30mm wide) banged in between the middle of the beam pair and the next brick below in the supporting internal brick walk. He has now gone...
Our chippy has chocked up the ends of the double beams (2 of c24; 170x47mm, bolted together) around our new stairwell with a short small softwood wedge (about 30mm wide) banged in between the middle of the beam pair and the next brick below in the supporting internal brick walk. He has now gone...