weather compensation

  1. eveares

    Do any Vaillant weather compensating controls support traditional hard wired thermostats?

    I have have a Vailant EcoTec Plus 937 boiler that is about 10 years old. During it's first few years, I had the VRC700f control with the wireless outdoor temperature sensor, that modulates the flow temperature based on the outside temperature. Unfortunately the outside weather temperature...
  2. W

    Vaillant EcoTec Plus 826 - is it too small and what controls to use?

    Evening all, I'm looking to have my 50 year old conventional boiler replaced with a combi, and may have a HWC added in a new location at a much later date. The current boiler is a Potterton Netaheat Electric 16/22. The teeth on the knob on the front have gone so the actual setting is somewhere...
  3. D

    Lukewarm rads and constantly cycling boiler

    Hi, we’ve got the vaillant ecoFit Sustain. Flow temp is set at 65. CH is calling for heat as per the NEST thermostat, but boiler gets to 41 and then starts to cycle and temp cools down. Rads only getting lukewarm. We did have the sensocomfort thermostat with the weather compensator probe...
  4. H

    Viessmann 222-f heating curve & other things

    Hi all, this is my first post so I apologise if this has been discussed. I have looked. Also apologise for very long post! I’ll be amazed if anyone actually reads this let alone answers the questions but it’s worth a shot! … We had a Viessmann 222-f fitted to our conversion house. It’s an old...
  5. thebaldfox

    Vaillant VR71, SensoComfort and NetSensor Gateway initial set up

    Just had boiler controller upgraded: Existing Ecotec 637 plus. We installed a VR71 / SensoComfort VRC720f / NetSensor Gateway Everything appears to be working. Tech support recommended system diagram 2 (we have single heating and HW circuits). We also added a second circulation pump. They...
  6. thebaldfox

    Vaillant Smart control - are my assumptions correct?

    Just took over a new property that has an EcoTEC pure 637 installed, separate HW cylinder, honeywell Evo home programmer (t6). I'm upgrading and have bought the following items after doing a bit of research and would like to get some confirmation of my assumptions: Purchased: VR71 - I have a...
  7. S

    Should I have room thermostats as well as a weather compensator

    Hi, I have conflicting information from 2 different plumbers/Viessmann itself and not sure what is correct. My system is a Viessmann vitodens 222-f which powers UFH downstairs and rads upstairs. We have no internal thermostats anywhere in the house and just work off of the weather compensator...
  8. H

    Intergas boiler combined with OpenTherm and Weather Compensation

    I have an Intergas Eco RF 36 with a T4R and weather compensation. I'm looking for my installer to change the current wiring over to OT. Having read a lot today, I'm confused as there lots of conflicting opinions as to whether WC and OT can work together without problems, but not what the...
  9. B

    Viessmann 200w with Multi Zones

    Merry xmas all I am replacing my creaking ideal mexico with a viessmann 200w 35kw 4 piped. Converting both CH and HW from vented to unvented. I currently have each room zoned off (radiator actuators) via a central controller (Loxone). 6 bedrooms, 3 bathrooms, kitchen and 3 reception rooms etc...
  10. Jaume Vila

    Vaillant VSMART: how to turn off weather compensation?

    Hi there. I have recently bought a VSMART control for my Vaillant boiler. I feel the weather compensation too intrusive, so that when the outdoor temperature is not too low, the load is very low and the temperature remains more than 1.5 ºC below the setpoint. So, is there a way to switch off...
  11. M

    Viessmann, Opentherm, Weather-Compensation, Evohome

    Hi Everyone, I've been searching online and came across this website which seemed to have knowledgeable contributors so thought I'd join to ask some questions about a planned new central heating system. Apologies for the long post whilst I set the scene. My house consists of a lounge, a...
  12. J

    Weather compensation on a Vaillant UFH & rad setup

    Am considering fitting the Vaillant weather compensator, the logic behind it makes sense to me but not sure if we have the right setup for it to work properly. Existing system is: 637 Plus system boiler UniStor cylinder Zone 1 - Radiators (upstairs & downstairs) with Honeywell room stat Zone 2...
  13. N

    Vaillant VRC 470 - how to advance the heating?

    Hey all, Apologies if this is a really silly question but I have has the VRC 470 installed with a Vaillant system boiler & Vaillant cylinder. Everything is working fine and I have learnt a lot about using the VRC 470 controller (which you need a master's degree in). However I am missing the...
  14. 1

    Viessmann 111-w

    Hi, I am considering purchasing the 35kw version of above boiler. What have been your experiences with this boiler? I am also considering purchasing the weather compensation sensor. Does anyone else have this on this particular model? I know that the weather compensation on the 200 range is...