Nice clear picture showing how to run and connect power sockets in a ring main. The picture indicates that the start and return of the ring main should be connected independently in the consumer unit. This is incorrect, the start of a ring should end at the same place on one circuit breaker.
Courtesy of RF Lighting
The socket supplied from the junction box could be labelled as a SPUR