Handle, or draw from it.
You can’t exceed the fuse and you may want to allow a buffer of 5-10%.
Like most things if the power available is going to be exceeded external power supplies maybe used
sounds like you have been playing 8 seconds was the default exit settle time if memory serves me correctly.
whats in the event log exactly.
E/E arming mode requires door to be opened and then closed and the exit settle time expires the system sets.
Do you have the correct arming setup for the...
I would compare the programming in both panels in the first instance for differences.
Silence what exactly?
I think your sying the chime isnt toggling on nd off with the chime button??
Make sure area text is assigned to the areas.
Only if you want to omit it part set two should it be on the list, as a rule entry exit zones are not omitted normally.
Hmmm
Interesting a udl lockout refers alledgedly to the likes of wintex or cloud connecting to the panel and the udl passcode not matching.
Wrt to seeing this with the expander and the keypad dropping out on a psu 200.
I think we need to look into this a little more,
How is it wired to the...
There should be a user over ride option in the cloud so it doesn’t need a user to authorise.
only master user from memory can authorise the firmware upgrade.
Otherwise a user has to authorise the upgrade, I guess it’s a safety thing, ie no upgrade whilst user unavailable.
Glad it’s working.
What versions of bell box and what mode?
Just the enforcer has a 500mA fuse on that board if I recall correctly. In alarm SAB mode for the odyssey range the siren could be greater than 500mA. It will sit pretty until the alarm goes off if the draw is greater than 500mA.
The...
60mA I think it says in the manual for Texecom, Orisec one can draw more and believe that has an terminal for back light control but would have to check to be certain.
Which siren you using as the Texecom one doesn’t have that option. Had to check the manual to make sure my memory wasn’t failing me.
The odyssey X LED back light wires into the 12V (A) and 0V (D) terminals.
So controlling the LED back light just need power to flow through it.
So what do you...
Yes.
Assuming it’s the compatible ie Premier Elite blah blah blah.
So currently you have ;-
Your site.
You add so sons site.
In App users you have the same email address assigned to your site and sons site.
You should get notifications for both sites if switched on.
In terms of arming...