  1. W

    Potterton e168

    Hi all, i have a potterton 28 he+ that been giving me an random e168 errors. so far Ive replaced the actuator, diverter cartride, pressure switch, temp sensors pcb and room stat (salus wireless). doesn't happen as frequently now but still there. usually more after having used hot water. im...
  2. R

    Baxi boiler and Hive

    Hi, I’ve got a baxi 28he platinum in a rental property. Its got an old back rf timer/thermostat that not longer works correctly so the heating has a mind of its own. I’m looking to replace it with a hive (or similar) but I’m unsure if it’ll be compatible. Any suggestions or help would be good...
  3. M

    NEST Heat Link Wiring - Half a job

    Afternoon All, I've been trawling threads and Google for help. We've recently had an extension built and a new boiler installed. On asking the plumber to install the Heat Link he stated not his job and on asking the electrician he stated the same. This went on until electrician agreed. Any how...
  4. S

    Wiring 2nd Generation Nest Heat Link to Baxi Duo-Tec 28 HE a

    Hi all, I think this is be a fairly simple job but just want to make sure I'm doing what I think I should before I go ahead with it. I need to install a wireless Nest thermostat (so not connected directly to the boiler). I have a Baxi Duo-Tec 28 HE a combi. Currently I have a Salus wireless...
  5. C

    Load fast Ticking from radiators

    All, I have not long had a new Baxi Platinum 28 Combi ErP boiler fitted. All was working well bar a few pressure cut outs recently and also there is a noise coming either the boiler or the pipes / rads. I done some checking and the noise is a rattling, ticking / pinking noise. It seems most...
  6. L

    baxi 105e changed pump still got a pump fault showing

    hi, firstly a bit of back ground. a couple of weeks ago the hot water pipe under our both blew off (due to the chap who fitted the bathroom before we bought the house not tightening a compression fitting properly) anyway this led to the hot water pumping out under the bath for around 20 mins...
  7. B

    Replacing a Conventional Boiler with Combi.

    I have an estimate to supply & fit a new Baxi Duotec 33 combi boiler to replace my old conventional boiler. I wonder if someone could have a look and let me know if this sounds fair? Drain and remove old boiler Alter pipework to suit Remove HW Cylinder Upgrade gas supply to 22mmm pipe Supply...
  8. A

    Hive Installation Baxi Combi Boiler

    Hi all I've got a Hive 2nd Gen thermostat and I'm looking for a guide on how to wire it in. I currently have a simple wired timer, 2nd picture below. This doesnt have the live connections the hive system requires. So I'm planning on taking a feed from the spur for the live and neutral...
  9. boothy01

    Hive & Baxi DuoTec 33 Combi Wiring Headache (Doesnt turn heating on)

    I'm having a nightmare trying to get the Hive unit I've got hold of working with the Baxi DuoTec 33 Combi Boiler I have at work. The Hive I have got has both the heating and water control buttons (so I believe it's the 2 channel one), but I believe despite this Hive unit being designed for...
  10. P

    Optimal boiler / shower configuration?

    Hi, we're currently having an extension built, and looking for some suggestions on the best options around boilers and showers please. The house is currently a 3 bed semi with one family bathroom (bath and shower), heated by a 30kW combi boiler. Our current combo boiler works fine but is...
  11. H

    Smell of gas on ignition from newly-serviced Baxi Solo 2 30PF boiler

    Hi all, I'm at my wits end after a week of boiler woes. Last Sunday we noticed a smell of gas coming from the boiler when the heating came on. We immediately called the Gas Emergency Services and someone came very quickly and detected that there was indeed a leak from the boiler. He shut the...
  12. M

    Heating programmer change

    Hi, first of all, great forum! Here's my situation. I have an old style (but fully working, serviced and reliable) gas central heating system, baxi boiler with hot water cylinder upstairs and a gravity fed tank in the loft. It has a danfoss set 5 programmer/controller. However the wall...
  13. L

    Baxi 80e combi boiler ignoring room thermsotat

    Hi, I've just moved into a property with a Baxi Combi 80e gas fired combi boiler. (http://www.baximarketing.co.uk/discontinued-literature/combi-boilers/Baxi-Combi-80e-105e-ins.pdf) Although this is quite an old and discontinued boiler and not the latest efficiency it does seem to work OK for...
  14. C

    Baxi Boiler Controller

    Dear all, I currently have a Baxi back boiler connected to a Wickes RWB9.cw controller. The controller is a bit faulty and so I am after a new controller. (Even though I do need a new boiler!!) Can anyone advise which is the best sort of controller to use? The house has radiators with stats...
  15. Coffee_drinker

    Baxi Megaflo 24HE boiler Central Heating constantly ON

    Baxi Megaflo 24HE boiler Unventend system Danfoss FP715-Si programmer Danfoss manual room thermostat Few months ago switched from Vented to Unvented. All worked perfectly until few days ago. Couple of days ago Central Heating came ON and it stays ever since. Room thermostat is turned down to...
  16. 3

    Baxi Bermuda back boiler with Randall 3060 control power issues

    Hi all, I have a Baxi Bermuda 552 back boiler which is working fine, however, when it kicks in on occasions it is tripping the power and those occasions are getting more frequent. It works fine once I flip the trip switch back. It usually happens when it first starts in the morning, but in the...
  17. 3

    Baxi Bermuda 552 back boiler and Randall 3060 control

    Hi all, I have a Baxi Bermuda 552 back boiler which is working fine, however, when it kicks in on occasions it is tripping the power and those occasions are getting more frequent. It works fine once I flip the trip switch back. It usually happens when it first starts in the morning, but in the...
  18. M

    Baxi Combi 80e, Water only warm, not hot.

    Evening all Recently moved house. New house has a Baxicombi 80e I had a problem with the hot water, the flow rate through the shower wasn't sufficient to trigger the hot water microswitch, unless I ran the washbasin tap first. Believed it to be the DHW Diaphragm, so replaced it. Genuine Baxi...