Hi. My Honeywell CM927 has finally given up so I’ve been researching smart heating controllers to replace it. I think I’ve settled on the Drayton Wiser two channel kit which is currently £99 at Screwfix.
Currently I have a Lifestyle LP241 which controls the water heating on a twice a day timer...
Hi all,
We've just moved into a new home and want to install a Drayton Wiser heating system here. I installed it at our last place but understood the plumbing set up a lot better and it was much simpler!
What we have is a combi boiler, as well as a hot water tank, and I think a cold water tank...
Hi, sorry for another Wiser thread but I can’t find an answer on any of the others.
I’ve bought a Drayton Wiser WV714R9K0902 and am struggling to install it.
The existing thermostat was a Honeywell with wiring shown on the attached picture.
Most of the other examples I’ve seen have a black...
Hi All,
I have a vented heating system where a Danfoss thermostat controller is used to schedule the central heating and hot water. I have two zones—upstairs and downstairs—which I turned to the maximum setting of 30°C so that they are always on.
When I opened the Danfoss controller, I saw...
I moved into a new house and bought a Wiser Hub & smart TRVs, having use them before. I had the hub connected to the boiler but when I tried to fit the TRVs they don't fit to the existing valves- the metal ring nut is a mm or two too big. I contacted Wiser with photos who said they didn't know...
Hi,
I have recently moved into a 3 story terraced house built in 2011. When I moved in, the house utilised a danfoss heating system that I wasnt familiar with. Inside the airing cupboard (which is situated on the top floor) was a danfoss FP715 Si 2 channel programmer for heating and hot water...
Evening all,
I've just bought a Drayton Wiser Kit 1 to replace my EPH Controls (RF1A-OT) and just want to clear something up with the wiring.
Here is the current wiring setup:
And here are the instructions for the Drayton Wiser Kit 1 (Combi Potterton boiler)
Am I missing anything from the...
Switching from an ESI ESRTP4RF+ to a Drayton Wiser with a Worcester Combi boiler (single zone/one channel)
The current wall plate wiring looks identical to the Drayton Wiser scheme, but just wanted to check if it would be plug n play.
Attached photos of current wiring on wall plate.
I...
Hey All, hoping to get me past the last hurdle of a Drayton Install Kit 1.
I currently have a 2 Zone system, however the upstairs zone valve has been opened by a plumber as I really didn't need two zones. 2 year old Ideal boiler.
Bought a Wiser Kit 1 and fitted it today. Images here
Based on...
I was about to change my Drayton LP722 to a Wiser model but just discovered the Wiser does not cater for gravity systems.
Although the water heating is theoretically gravity, because of the distance and height difference between boiler and hot water tank it needs to be pumped to circulate...
I came accross what I consider a ridiculous flaw in the Drayton Wiser system which I have requested Drayton to address.
I had deactivated the schedules for all rooms while the system was being worked on so no rooms had an assigned climate schedule. The system had been fine in this off state for...
Hi I've just moved to a new house and I’m looking to replace my current heating system controls with a Drayton Wiser smart system.
I have an Ideal Vogue Max System 32 boiler with water tank, a basic Drayton thermostat that controls hot water on a timer and a Salus thermostat. I also have a...
Hi everyone, hoping there are some knowledgeable people here who can help me understand what's going on with my Wiser and boiler setup, and hopefully reassure me that it's not causing unnecessary wear and tear on my boiler...
Boiler is a Worcester Greenstar 30 CDi Classic Regular ErP and I...
Hi All,
I'm trying to fit drayton wiser thermostat to connect to opentherm on alpha evoke 33. The existing boiler is fitted with the basic alpha wireless thermostat.
I wired the new thermostat to the opentherm to the 41 and 44 and switched the P7 to 1 as described in the documentation.
The...
Last year I had a new combi boiler installed alongside the Drayton Wiser smart hub system.
This is the boiler: Ideal Logic Combi Boiler
This is the controller system: Drayton Wiser Kit 1
I didn't know at the the time that the installer could wire it NOT using the OpenTherm module. I want to...
Hi,
I have just bought a Drayton Wiser kit 1.
I have a Salus and trying to replace with the Drayton Wiser.
Please could you help me switch the two over?
HI all. I have got a Worcester greenstar 28i junior combo boiler. The thermostat currently on there is a worcester digistat. This digistat talks to the boiler via RF. I am looking to get the Drayton Wiser thermostat system but want to check it will be compatible with the boiler.
To add...
Hi, please can someone help me. I have tried for days but cannot do it.
Currently I have 2 zones and hot water run off a conventional boiler.
The sytem works perfectly with my ST9100C1006 and the 2 thermostats (CM927, and CM907).
I am looking to replace all with Drayton Wiser, mainly for smart...
Hi, I've joined because I have a lot of trouble with trying to make my new boiler work with the Opentherm interface and thought someone with more experience than me could help.
Equipment:
Drayton Wiser - Single Channel Programmer with Opentherm module.
Baxi 836 Combi boiler with Opentherm...
Hello fellow users,
I have a wired non-smart Danfoss thermostats system that I am trying to replace with Drayton Wiser 3 kit but running into some issues where I would like your knowledge and expertise.
The current system is:
TP9000 controlling ground floor heating and overall Water of the...