texecom alarm

  1. FreezinOnSite

    Texecom 32XP-W won't learn devices and other questions

    Hi Everyone Looking for some advice on my alarm setup (I don't have all the history of the install since it was done by the previous owners)... 1. In engineer mode, when I hit 'yes' on the 'YES to select Learn Ricochet' it immediately says 'All Devices Learnt!' but when I select the reset...
  2. R

    Texecom 'Zone Doubling'

    Hi all.. I recently bought a Texecom Premier Elite 64W. I have 4 core cabling in certain areas throughout the house for the pir sensors and then various other places such as the garage but since have had an outbuilding built and new doors which i wanted to add some wireless detectors to hence...
  3. J

    Texecom - changing siren battery

    Hey, I have the Elite 64 Panel with a siren outside which I believe is the Odyssey X. I've just been alerted that it's on low battery. I thought it would be a simple job of just replacing the AA batteries inside, but having read the manual it seems not. It seems I have to; Activate the strobe...
  4. D

    Installing External LED to Texecom Elite 24

    Hi, I have a Texecom Premier Elite 24 with Smartcom module. I have a programmed a “Bedtime alarm” to arm all doors and downstairs PIR’s. I have fitted an external LED in my hallway which I hoped would illuminate when the alarm is part set to remind other family members, first thing in the...
  5. W

    Texecom Premier Elite - Help - Cant clear Supervisor Fault/No RF Signal

    Warning: this is a long post. Thank you in advance if you have the patience to read. Hi, I had an Texecom Premier Elite alarm system installed around 3 years ago. The alarm company that I used have been pretty bad on the customer service front (hence why I havnt just gone back to them with...
  6. L

    Texecom Elite

    Hi we have had a texecom elite alarm system fitted. When setting the alarm the speaker produces a chirp which is a high frequency sound. Unfortunately I can not hear the chirp so do not know the alarm has been set or not. (Partially deaf at high frequency) Any ideas what can be done? Many thanks
  7. J

    Texecom 'A System Low Battery Alarm Occured'

    Hi, I've just got a texecom connect notification that 'A System Low Battery Alarm Occured'. I'm wanting to find out what this means? I'm a total Texecom newbie but i'm wanting to see if I can sort it out myself rather than calling the installer back for a charge. I've had it around 2 years now...
  8. P

    Smart key fob learning issues

    Hi everyone I am having annoying issue with my smart keys which no longer connecting after having the panel firmware updated. Tried relearning the keys but the 20second timer runs down but key does not get paired again. I have followed the Texecom YouTube video to the letter. Any help is very...
  9. Pinstrypsoldier

    Disconnected alarm, lights still flashing on bell box

    Hi all. I’ve used this site a few times but only just now signed up to post something of my own! I had a smart meter fitted recently and during the installation, the power had to be disconnected. When this happened, the alarm sounded for 15 minutes (presumably because the battery is old/dead)...
  10. J

    Texecom Connect - ACK Failed

    Hi, I'm setting up my texecom connect via the Texecom keypad. After linking up Com 1 & Com 2, I am trying to get the Texecom Connect App Code via the keypad. When trying to enable Texecom Connect, I get the following error message on the keypad; ACK Failed Call Terminated Any ideas? The...
  11. A

    Texecom RKP zones just not working

    Hi folks, I have a Texecom Premier 24 panel that i put in a few years ago and am now adding a second wired RKP for the garage - with a Premier PIR and a CQR 517 magnetic door contact to install. Can anyone advise how to wire these into the RKP's zones to pass through? I just can't get them...
  12. J

    Problem Arming Failed Alarm

    Premier Elite 88 Premier Elite AMQD Having an intermittent problem with arming. It seems to be linked to the zone that looks towards the keypad and one of the entrance doors. The zone in question is set to Guard/Access. Any ideas why this setup could be causing the arming problems? Thanks
  13. J

    Installation of a Texecom V5 elite alarm. How do you connect the PIR TO THE PANEL

    I have recently fitted a texecom elote v5 panel and have followed the wiring instructions for the keypad and strobe and that is all good. I have one pir for each zone 6 in total for a 8 zone panel so 2 zones won’t be used. The PIR has 6 wires connected to them but don’t know how to terminate the...
  14. H

    Texecom Premier Alarm Faulty Door Sensor

    Hi all, I am hoping for some help with a family member's alarm system that was installed at the same time the house was built. It is a Texecom Premier alarm and the main door sensor seems to be faulty. I have armed the sytem with the door shut and the exit beep is still intermittent rather than...
Back
Top