Hi everyone,
I have just tried to install Hive to my CH system and that didn't go well,
I have got Ideal Logic Heat 12, Danfoss TP9000 Si, Danfoss TP5000 Si and small remote room temp sensor in the hall. The heating is twin zone heating + hot water cylinder. When I replaced Danfoss TP9000 Si...
Hi,
I have today wired up the Hive thermostat, receiver and hub.
Connected up the wires how they were on the old receiver and now the boiler is not working. Works from the main thermostat to receiver, but doesn’t action the boiler.
Have now taken off the plate on the boiler and can see...
Hi all
Puzzling one which my local heating engineer can't solve, who gave the boiler a clean bill of health but doesn't know much about Hive.
I'm obviously not an engineer but I'm convinced the Hive wiring is at fault here somehow. The system was installed before we moved in. I found a similar...
I've read several threads on here about Hive installs, seems to be a fairly popular DIY job!
I've also watched a few YouTube videos -and decided I would buy: https://www.screwfix.com/p/hive-active-heating-hot-water-thermostat/5215j?_requestid=284429
This may be a stupid question but want to...
Hi, I’m looking for some advice if anyone can help. I have an ideal logic 30 combi boiler and have fitting hive smart thermostat. I wired up the receiver correctly (I think) but the receiver doesn’t fire the boiler up when requested. The boiler currently only has a dial type timer fitting in the...
I see this has been asked may times and already some suggestions, just wanted to check my particular set up before wasting my 2 days off work!
1)Currently have BG UP1L(RWB9) Programmer. Can this be straight swapped with Hive 3, ie click on without rewiring?
2)If it does, next up is Thermostat...
Hi all,
I am in the process of updating our heating controls. Looking to install Hive as we had it at a previous house and simply want to utilise the app as we work shift work so do not have set schedules.
I am looking to install this myself as I always like to attempt in the first instance...
Have searched the site for solution and couldn't find one for my problem, hopefully someone is able to advise on where I have went wrong.
Formerly had potterton EP2002 controller connected to my BAXI system boiler 60/100. (See photo)
This also had a thermostat wired in and has a hot water...
I hope someone can help,
We have a Mitsubishi ground source heat pump system with a water cylinder with a Mitsubishi PAC-IF013B-E Unit on the front.
Downstairs we have a wireless Danfoss TP500Si thermostat which talks to the Danfoss RX1 single channel receiver also attached to the unit.
There is...
Hi all,
I hope someone can help. I recently purchased a hive dual channel receiver for my Worcester boiler which works alongside an immersion tank. The existing system was a Honeywell setup consisting of:
- Wireless thermostat (battery powered in hallway)
- BDR91 Wireless relay box (in cupboard...
An assistance wiring my Hive will be greatly appreciated.
I have the Heating and hot water hive product as I have a system boiler. The water tank is on the first floor and boiler on the ground floor.
The programmer I want to replace is the horstmann h27xl, which is accompanied by the horstmann...
Hi all,
I bought a Hive active heating system to replace the current set up which is the EPH wireless receiver WRS1i for my Worcester Combi boiler. I thought (perhaps stupidly) that the set up would be easy and I could avoid a BG install! When I opened the EPH receiver I realised I'm actually...
Hello,
Can you please advise me if my wiring diagram looks correctly? I've ordered few days ago Hive without installation and from what I've gathered that seems how it should be looking like, but I would ideally need confirmation from somebody that knows better then my very amateurish skills...
Looking for some help fella’s
installing a single channel receiver into a systems that has a emt2 and a wired thermostat.
I have tried everything...... as it’s all taken off I only have a diagram of how it was originally wired. All in twin and earth btw
the 240v spur went to the L,N of the...
Hi
I've got a combi boiler with a British Gas WPT1 wireless thermostat and hive single channel receiver.
I'm thinking about upgrading to a full hive system to be able to use the mobile app etc, so could anyone tell me, can I just buy the hive hub and continue using the BG WPT1 thermostat and...
Looking for some help / guidance to replace our existing Honeywell cm921 thermostat with a Hive. I've removed the faceplate and there is a red wire connected to A a yellow wire connected to B and a blue wire going to one end of a terminal. I can also see a green/yellow wire behind this not...
Could someone please take a look at my Boiler/Hive set up and let me know what I need to do to install:
1 x HIVE single channel Receiver
I have;
1 x heating valve installed and ready to go (black wire in red box), which will feed my garage conversion consisting of 3 radiators (heating only...
Hi all
Bought myself an early Xmas pressie and will be swapping out an old Danfoss 102 with a single channel Hive.
I’m no expert, so could I please ask for a logic check on the wiring.
L / N / E & Common I’m ok with.
It’s the black wire - Danfoss position #1 that I’m looking for - I think...
Hi all,
Hopefully you can help me with what seems a simple wiring task.
I have just purchased the Hive kit and am trying to replace the existing Siemens Landis & Staefa RAA02.1N thermostat with the new Hive Receiver.
There are just 2 wires and an earth wired up and it useds the following...