hive

  1. S

    Hive/boiler help!

    Hi, I’m looking for some advice if anyone can help. I have an ideal logic 30 combi boiler and have fitting hive smart thermostat. I wired up the receiver correctly (I think) but the receiver doesn’t fire the boiler up when requested. The boiler currently only has a dial type timer fitting in the...
  2. Mbgmark

    Hive Backplate Compatibility

    I see this has been asked may times and already some suggestions, just wanted to check my particular set up before wasting my 2 days off work! 1)Currently have BG UP1L(RWB9) Programmer. Can this be straight swapped with Hive 3, ie click on without rewiring? 2)If it does, next up is Thermostat...
  3. S

    Hive heating wiring - bdr91

    Hi all, I am in the process of updating our heating controls. Looking to install Hive as we had it at a previous house and simply want to utilise the app as we work shift work so do not have set schedules. I am looking to install this myself as I always like to attempt in the first instance...
  4. E

    Baxi 60/100 and Hive

    Have searched the site for solution and couldn't find one for my problem, hopefully someone is able to advise on where I have went wrong. Formerly had potterton EP2002 controller connected to my BAXI system boiler 60/100. (See photo) This also had a thermostat wired in and has a hot water...
  5. JK5599

    Why do I have 2 receivers??

    I hope someone can help, We have a Mitsubishi ground source heat pump system with a water cylinder with a Mitsubishi PAC-IF013B-E Unit on the front. Downstairs we have a wireless Danfoss TP500Si thermostat which talks to the Danfoss RX1 single channel receiver also attached to the unit. There is...
  6. B

    Honeywell To Hive Dual Receiver Help Please!

    Hi all, I hope someone can help. I recently purchased a hive dual channel receiver for my Worcester boiler which works alongside an immersion tank. The existing system was a Honeywell setup consisting of: - Wireless thermostat (battery powered in hallway) - BDR91 Wireless relay box (in cupboard...
  7. P

    Hive installation, assistance needed

    An assistance wiring my Hive will be greatly appreciated. I have the Heating and hot water hive product as I have a system boiler. The water tank is on the first floor and boiler on the ground floor. The programmer I want to replace is the horstmann h27xl, which is accompanied by the horstmann...
  8. E

    Replacing EPH WRS1i with Hive - Help!

    Hi all, I bought a Hive active heating system to replace the current set up which is the EPH wireless receiver WRS1i for my Worcester Combi boiler. I thought (perhaps stupidly) that the set up would be easy and I could avoid a BG install! When I opened the EPH receiver I realised I'm actually...
  9. P

    Hive to Potterton 28 wiring

    Hello, Can you please advise me if my wiring diagram looks correctly? I've ordered few days ago Hive without installation and from what I've gathered that seems how it should be looking like, but I would ideally need confirmation from somebody that knows better then my very amateurish skills...
  10. Hamilton1985

    Another HIVE howler....

    Looking for some help fella’s installing a single channel receiver into a systems that has a emt2 and a wired thermostat. I have tried everything...... as it’s all taken off I only have a diagram of how it was originally wired. All in twin and earth btw the 240v spur went to the L,N of the...
  11. D

    hive thermostat wiring

    I've just wired up hive thermostat but what do i do with the old room thermostat wires
  12. S

    Will a BG WPT1 work with Hive Hub?

    Hi I've got a combi boiler with a British Gas WPT1 wireless thermostat and hive single channel receiver. I'm thinking about upgrading to a full hive system to be able to use the mobile app etc, so could anyone tell me, can I just buy the hive hub and continue using the BG WPT1 thermostat and...
  13. H

    Replacing Honeywell cm921 with Hive

    Looking for some help / guidance to replace our existing Honeywell cm921 thermostat with a Hive. I've removed the faceplate and there is a red wire connected to A a yellow wire connected to B and a blue wire going to one end of a terminal. I can also see a green/yellow wire behind this not...
  14. 98webp

    HIVE EXTRA THERMOSTAT INSTALL

    Could someone please take a look at my Boiler/Hive set up and let me know what I need to do to install: 1 x HIVE single channel Receiver I have; 1 x heating valve installed and ready to go (black wire in red box), which will feed my garage conversion consisting of 3 radiators (heating only...
  15. B

    Danfoss 102 to Hive Single Channel

    Hi all Bought myself an early Xmas pressie and will be swapping out an old Danfoss 102 with a single channel Hive. I’m no expert, so could I please ask for a logic check on the wiring. L / N / E & Common I’m ok with. It’s the black wire - Danfoss position #1 that I’m looking for - I think...
  16. B

    Hive Installation Help

    Hi all, Hopefully you can help me with what seems a simple wiring task. I have just purchased the Hive kit and am trying to replace the existing Siemens Landis & Staefa RAA02.1N thermostat with the new Hive Receiver. There are just 2 wires and an earth wired up and it useds the following...
  17. D

    Hive wiring

    Currently about to set up hive active heating with a combi boiler so bought the single channel receiver. Already have a wireless receiver in place which I am to replace however unsure of the wiring was wondering if I could get some help. Have posted pics of current setup and the hive setup that...
  18. Dee Dee Houghton

    Hive Active Heating replacing Alpha RF Receiver

    Good Evening Gentlemen, I am going to replace my current Alpha Evoke Combi Boiler RF Climatic Controller with a Hive and just had 2 questions that you may be able to help me with. 1. I assume the hive signals for HW on and Heat on are the RF controller signals in picture 1 (Terminals 44 & 41)...
  19. WKDONE

    Replace old Analogue with HIVE

    I've bought my HIVE in the black Friday sale last year and have been waiting for the local plumber to install but he keeps fobbing me off.... so can anyone advise me on how to wire this up.... I've been through all the usual tutorials and can't make sense of them because they're all different...
  20. luke104123

    Multi zone Hive installation

    Hi all. Hoping for some advice here on installing two Hive receivers to my Logic 35 Combi boiler. I have explored the existing Hive threads but my setup seems a little bit more involved. I currently have two zones in a new build house, one downstairs and the other upstairs. Here is where I...